Top 10 Budget-Friendly Basic PDUs for Home Labs This Year

A Basic PDU efficiently distributes power to all devices within a home lab. It serves as a crucial component, ensuring consistent electrical supply for servers, switches, and other networking equipment. Unlike an Intelligent PDU, a Basic PDU focuses solely on reliable power delivery without advanced monitoring or remote control features. This guide helps users discover the best budget-friendly Basic PDUs for their setup this year. Selecting the right unit ensures stability and organization for any home lab environment.

Key Takeaways

  • A Basic PDU gives power to all devices in a home lab.
  • Choose a PDU with enough outlets for your devices.
  • Match the PDU’s plug type to your wall outlet.
  • Look for safety features like surge protection and circuit breakers.
  • Mount the PDU securely in your rack or cabinet.
  • Manage cables well to keep your lab neat and cool.
  • Do not plug one PDU into another PDU.
  • Regularly check your PDU for any loose parts or damage.

The Top 10 Budget-Friendly Basic PDUs for Home Labs

This section highlights the top budget-friendly Basic PDUs available for home labs. Each review provides key features, advantages, disadvantages, and suitability for a home lab environment.

Tripp Lite Basic PDU PDU12IEC

Key Features

The Tripp Lite PDU12IEC is a robust power distribution unit. It handles 100-240V AC input and outputs 240V AC. This unit features an IEC 60320 C20 plug type. It provides 14 outlets, including 12 IEC 60320 C13 and 2 IEC 60320 C19 receptacles. The PDU offers a 16 amp capacity. It supports versatile mounting options. Users can install it as 1U rackmount, 0U vertical rackmount, wall-mount, or under-counter. The design includes a rugged all-metal case. It also has a back panel grounding lug. This Basic PDU comes with a 5-year limited warranty.

Pros

This PDU offers high power capacity. Its multi-voltage compatibility suits various global power standards. The numerous outlet types (C13 and C19) support diverse lab equipment. Versatile mounting options provide flexibility in rack or cabinet setups. The durable metal construction ensures long-term reliability.

Cons

The PDU lacks a power switch. This means users must disconnect the input cable to power it off. The IEC-320 C20 input plug might require a specific input cable. This could be an additional purchase for some users.

Home Lab Suitability

The Tripp Lite PDU12IEC is an excellent choice for home labs. It provides reliable power distribution. Its high outlet count accommodates many devices. The flexible mounting options fit various lab configurations. This PDU handles demanding power requirements effectively.

CyberPower Basic PDU CPS1220RM

Key Features

The CyberPower CPS1220RM is a 1U rackmount power distribution unit. It operates with an input voltage of 100-125V AC. The unit delivers 120V AC output. It has a 20 amp input current. This PDU features a NEMA 5-20P plug type. It offers 12 NEMA 5-20R outlets, with six on the front and six on the rear. The power rating is 1800 VA. It includes overload and short circuit protection. A 15-foot power cord provides ample reach. The unit is ETL/RoHS certified and UL Listed. It also features a cord retention tray.

Pros

The CyberPower CPS1220RM provides robust power protection. Its overload and short circuit features safeguard connected equipment. The 12 outlets offer ample connectivity for multiple devices. A long power cord enhances placement flexibility. The dual-sided outlet distribution (front and rear) helps with cable management.

Cons

This PDU operates within a specific voltage range (100-125V AC). It may not suit international home lab setups. The NEMA 5-20P plug requires a compatible 20A circuit. Standard 15A household outlets will not work without an adapter.

Home Lab Suitability

This CyberPower PDU is highly suitable for home labs. It uses standard North American power infrastructure. Its high outlet count and protection features make it ideal for server racks. The cord retention tray helps maintain an organized setup.

NBYOSUN Basic PDU 8-Outlet Rackmount

Key Features

The NBYOSUN 8-Outlet Rackmount is a straightforward power distribution unit. It typically features an 8-outlet design. These outlets are usually NEMA 5-15R type. The unit often comes in a 1U rackmount form factor. It includes a standard NEMA 5-15P input plug. A built-in circuit breaker provides basic overload protection. The PDU usually has a durable metal casing.

Pros

This PDU offers simplicity and ease of use. Its compact 1U design saves rack space. The standard NEMA 5-15R outlets are compatible with most home lab equipment. It provides essential power distribution at a budget-friendly price.

Cons

The NBYOSUN PDU has fewer outlets compared to other models. It typically lacks advanced features like individual outlet control or metering. Its 15A capacity might limit the number of high-power devices.

Home Lab Suitability

The NBYOSUN 8-Outlet Rackmount is perfect for smaller home labs. It suits setups with fewer devices or lower power requirements. Its cost-effectiveness makes it an attractive option for beginners. It provides reliable basic power distribution without unnecessary complexities.

APC Basic Rack PDU AP9562

Key Features

The APC Basic Rack PDU AP9562 offers reliable power distribution. It comes in a 1U form factor. This unit provides essential power to rack-mounted equipment.

Specification Detail
Model AP9562
Type APC Rack PDU, Basic, 1U
Input Voltage 100V, 120V
Input Connection NEMA 5-15P
Cord Length 12 feet (3.66 meters)
Output Voltage 120V
Output Connections (10) NEMA 5-15R
Included Components Installation guide, Rack Mounting brackets

Pros

This PDU is a simple, strong device. It performs its job effectively. Users consider it an economical choice. It helps keep costs low for home lab builders. The AP9562 provides reliable power for basic needs. It suits small to medium server rooms well. Its 10 NEMA 5-15R outlets offer ample connectivity. The 12-foot cord provides good reach.

Cons

The APC AP9562 is a basic unit. It lacks advanced features like metering or remote control. It only supports 100V or 120V input. This limits its use in regions with different voltage standards. The NEMA 5-15P input plug requires a standard 15A outlet.

Home Lab Suitability

The APC Basic Rack PDU AP9562 is an excellent choice for many home labs. It delivers dependable power distribution. Its cost-effectiveness makes it attractive for budget-conscious users. It handles typical home lab equipment power needs efficiently.

StarTech.com Basic PDU RKPW081915

Key Features

The StarTech.com RKPW081915 is a robust power distribution unit. It features a compact design. This PDU provides essential power for rack equipment.

  • Outlets: 8 NEMA 5–15 AC outlets.
  • Power Output: Delivers 120V 15A power.
  • Construction: Features a rugged steel casing for durability.
  • Indicators: Two front LEDs for ground and surge detection.
  • Power Control: Includes an illuminated power/reset switch.
  • Safety: Equipped with a built-in circuit breaker.
  • Form Factor: 1U rackmount, with a depth of 4 inches.

Pros

This Basic PDU offers strong durability with its steel casing. The built-in circuit breaker protects connected devices from overloads. Front LEDs provide quick status checks for ground and surge protection. An illuminated power/reset switch offers convenient control. Its compact 1U design saves valuable rack space.

Cons

The StarTech.com RKPW081915 has only 8 outlets. This might be insufficient for larger home labs. It operates at a standard 15A capacity. This limits the total power draw of connected equipment. It lacks advanced features like individual outlet control or power monitoring.

Home Lab Suitability

This StarTech.com PDU is ideal for smaller home labs. It suits setups needing reliable power for a moderate number of devices. Its safety features and durable build provide peace of mind. The compact form factor fits well in shallow racks or cabinets.

Eaton Basic PDU EBA101-10

Key Features

The Eaton Basic PDU EBA101-10 provides reliable power distribution. It typically features a 1U rackmount design. This model often includes 10 NEMA 5-15R outlets. It operates with a 120V input and output. A 15A circuit breaker offers overload protection. The unit usually comes with a NEMA 5-15P input plug. Eaton constructs these PDUs with durable materials for long-term use.

Pros

Eaton is a reputable brand known for quality power solutions. This PDU offers solid construction and dependable performance. The 10 outlets provide good connectivity for various devices. Its built-in circuit breaker enhances safety. The standard input and output make it easy to integrate into most home lab setups.

Cons

The EBA101-10 is a basic model. It does not include advanced features like power metering or remote management. Its 15A capacity might be a limitation for power-hungry equipment. Some users might find the price slightly higher than other entry-level options.

Home Lab Suitability

The Eaton Basic PDU EBA101-10 is a strong contender for home labs. It offers the reliability and build quality associated with the Eaton brand. It suits users who prioritize dependable, no-frills power distribution. This PDU is perfect for powering servers, switches, and other networking gear consistently.

Vertiv Basic PDU MPH2-1000

Key Features

The Vertiv Basic PDU MPH2-1000 provides reliable power distribution. It typically features a 1U rackmount design. This model often includes multiple NEMA 5-15R outlets. It operates with a 120V input and output. A built-in circuit breaker protects connected equipment from overloads. The unit usually comes with a NEMA 5-15P input plug. Vertiv constructs these PDUs with robust materials, ensuring long-term durability.

Pros

Vertiv is a well-regarded brand in data center infrastructure. This PDU offers dependable performance and solid construction. Its multiple outlets provide ample connectivity for various devices. The integrated circuit breaker enhances safety by preventing overloads. Standard input and output connections make it easy to integrate into most home lab setups.

Cons

The MPH2-1000 is a basic model. It does not offer advanced features like power metering or remote management. Its 15A capacity might limit the number of power-intensive devices it can support. Some users might find its price point slightly higher than other entry-level options.

Home Lab Suitability

The Vertiv Basic PDU MPH2-1000 is a strong contender for home labs. It delivers the reliability and build quality associated with the Vertiv brand. It suits users who prioritize consistent, no-frills power distribution. This PDU effectively powers servers, switches, and other networking gear.

Black Box Basic PDU RM080A

Key Features

The Black Box Basic PDU RM080A is a robust power distribution unit designed for higher voltage environments. It offers specific technical specifications for demanding setups.

Feature Specification
Input
Input Voltage 200-240 VAC
Input Current 16A
Input Frequency 50/60 Hz
Input Connector IEC 60309 2P+E 16A (IP44)
Cord Length 3 m (9.8 ft.)
Output
Output Receptacles (8) IEC 60320 C13
Overload Protection (2) 16A Circuit Breakers
Physical
Dimensions 4.4H x 48.2W x 6.2D cm (1.7″H x 19″W x 2.4″D)
Mounting Horizontal 1U
Weight 1.2 kg (2.6 lb.)
Environmental
Operating Temperature 0 to 60° C (32 to 140° F)
Storage Temperature -20 to 65° C (-4 to 149° F)
Operating Humidity 5 to 95% non-condensing
Compliance
Agency Approvals CE, LVD, EMC, RoHS
Warranty 3 Years
Included
Included (1) PDU, (1) User Manual, (1) Rackmount Kit
Optional Accessories
Optional Accessories IEC 60320 C14 to C13 Power Cords (various lengths)
Part Number
Part Number RM080A
Description
Description Basic PDU, 200-240VAC, 16A, 8 x C13 Outlets, IEC 60309 16A Input, 1U Horizontal Rackmount
UPC
UPC 650308008000

Pros

This Black Box PDU supports higher input voltages (200-240 VAC). This makes it suitable for international labs or specific high-power equipment. It includes two 16A circuit breakers, offering robust overload protection. The 8 IEC 60320 C13 outlets provide standard connectivity for server equipment. Its 1U horizontal rackmount design saves space. The durable construction ensures reliability.

Cons

The IEC 60309 2P+E 16A input connector is not a standard household plug in many regions. Users might need a specialized outlet or adapter. It offers only 8 outlets, which might be insufficient for larger home labs. This model lacks advanced features like power monitoring or remote control.

Home Lab Suitability

The Black Box Basic PDU RM080A is an excellent choice for home labs with higher voltage requirements. It suits users running enterprise-grade equipment that operates on 200-240V. Its robust protection and standard C13 outlets make it a reliable power distribution solution.

Legrand Basic PDU 0U Rackmount

Key Features

The Legrand Basic PDU 0U Rackmount (LP-21100) offers a space-saving design for efficient power distribution. It provides numerous outlets in a vertical form factor.

Feature Specification
PDU Type Basic
Plug/Connector Type NEMA 5-15P
Receptacle Type NEMA 5-20R
Receptacle Detail 14 x NEMA 5-20R
Input Current 12 A
Mount Type Rack-mountable
Rack Height 0U
Height 2.8″
Width 5.1″
Length 46.5″
Weight (Approximate) 4.29 lb
Manufacturer Part Number LP-21100
Limited Warranty 2 Year
Country of Origin China

Pros

This Legrand PDU features a 0U rackmount design. This allows vertical mounting in a rack, saving valuable horizontal space. It offers a generous 14 NEMA 5-20R outlets, providing extensive connectivity. The NEMA 5-15P input plug is compatible with standard household 15A outlets. Its lightweight design makes installation easy.

Cons

The 12A input current limits the total power draw. This might be a concern for very power-hungry home labs. The NEMA 5-20R receptacles are not compatible with standard NEMA 5-15P plugs without an adapter. Users must ensure their equipment has NEMA 5-20P plugs or use appropriate adapters. It lacks advanced features such as metering or remote control.

Home Lab Suitability

The Legrand Basic PDU 0U Rackmount is highly suitable for home labs needing many outlets in a compact form factor. Its 0U design is perfect for maximizing rack space. It provides reliable power distribution for a wide range of networking and server equipment.

Monoprice Basic PDU 10-Outlet Rackmount

Key Features

The Monoprice Basic PDU 10-Outlet Rackmount provides reliable power distribution for home lab equipment. This unit typically features a 1U rackmount design, making it suitable for standard server racks. It includes ten NEMA 5-15R outlets, offering ample connectivity for multiple devices. The PDU operates with a 120V input and output, and it usually has a 15A capacity. A built-in circuit breaker protects connected devices from overloads. The unit comes with a standard NEMA 5-15P input plug, ensuring compatibility with common household outlets. Its durable metal casing provides long-lasting performance.

Pros

This Monoprice PDU offers excellent value for its price. The ten NEMA 5-15R outlets provide sufficient power connections for a growing home lab. Its 1U rackmount form factor efficiently uses rack space. The integrated circuit breaker enhances safety by preventing electrical overloads. Users find the standard NEMA 5-15P input plug convenient for easy setup. The robust metal construction ensures durability and reliability.

Cons

The Monoprice Basic PDU lacks advanced features such as power metering or remote control capabilities. Its 15A capacity might limit the total power draw for very demanding home lab setups. Users with high-power servers or multiple power-hungry devices might need a higher amperage PDU. The unit does not offer individual outlet control, meaning all connected devices receive power simultaneously.

Home Lab Suitability

The Monoprice Basic PDU 10-Outlet Rackmount is an ideal choice for budget-conscious home lab enthusiasts. It provides essential power distribution without unnecessary complexities. This PDU suits small to medium-sized home labs with moderate power requirements. It reliably powers servers, network switches, and other rack-mounted equipment. Its straightforward design and ease of use make it a popular option for beginners and experienced users alike.

How to Choose the Right Basic PDU for Your Home Lab

How to Choose the Right Basic PDU for Your Home Lab

Selecting the correct power distribution unit ensures the stability and efficiency of a home lab. Users must consider several factors before making a purchase. This section guides individuals through essential considerations and different PDU types.

Essential Factors for Your Basic PDU Selection

Outlet Count and Type

Users must determine the number and type of outlets needed. Home labs often contain various devices. These devices include servers, switches, and network appliances. Matching the PDU’s outlets to equipment plugs prevents compatibility issues.

Form Factor and Mounting Options

PDUs come in different form factors. These include 1U rackmount, 0U vertical, wall-mount, and under-counter designs. The chosen form factor should fit the available space in the rack or cabinet. Proper mounting ensures organization and airflow.

Surge Protection and Circuit Breakers

Safety features are paramount. A PDU with surge protection safeguards equipment from power spikes. Integrated circuit breakers prevent overloads. Users should look for certifications like UL Listed or the CE Mark. These certifications confirm the product meets safety standards. The IEC CB Scheme (IEC 62368-1) also indicates compliance with international safety requirements for IT equipment.

Amperage Rating and Input Plug

The PDU’s amperage rating must match the total power draw of connected devices. A server with a w3495x processor can draw around 1100W at peak. Smaller devices, such as a cable modem (approximately 25W) or two Raspberry Pis via PoE (approximately 5W each), consume much less. The input plug type must also be compatible with the available power outlet.

Cord Length and Orientation

A sufficiently long power cord offers flexibility in PDU placement. Cord orientation (e.g., straight or angled) can also affect cable management. Users should choose a cord length that reaches the power source without excessive slack or tension.

Budget Considerations for Basic PDUs

Basic PDUs offer a cost-effective solution for power distribution. They provide essential functionality without advanced features. Users can find reliable options within a reasonable budget.

Understanding Different PDU Types

Horizontal vs. Vertical Basic PDUs

Horizontal PDUs typically mount within a 1U rack space. They distribute power across the width of the rack. Vertical (0U) PDUs mount along the side of a rack. They save horizontal space and often offer more outlets.

Basic vs. Metered vs. Switched PDUs for Home Labs

Users should understand the differences between PDU types.

PDU Type Core Functionality Data Granularity
Basic PDU Delivers electrical power to IT devices. None; acts as an outlet strip.
Metered PDU Delivers electrical power and provides information about power consumption. Can provide total PDU consumption (voltage, current, power, kWh, etc.) or detailed data for each individual outlet.

Basic PDUs have a lower initial investment. Their simpler design lacks advanced features. Metered PDUs, with integrated monitoring capabilities, typically have a higher upfront cost. Switched PDUs offer full monitoring capabilities. They also allow remote control of individual outlets. This enables operators to manage critical loads and schedule downtime. Switched PDUs often come with a higher price tag.

Single-Phase vs. Three-Phase Power

Most home labs operate on single-phase power. This is standard for residential electrical systems. Three-phase power is common in commercial data centers. It provides more efficient power delivery for high-density environments. Home lab users typically do not require three-phase PDUs.

Setting Up Your Basic PDU and Best Practices for Home Labs

Setting Up Your Basic PDU and Best Practices for Home Labs

Proper setup and adherence to best practices ensure the longevity and efficiency of a home lab. Users must correctly install and manage their power distribution units. This section outlines essential steps for PDU installation and optimization.

Installation Steps for Your Basic PDU

Mounting the PDU Securely

Users should mount the PDU firmly within the rack or cabinet. For 1U rackmount PDUs, secure them with appropriate rack screws. Ensure proper alignment with other rack-mounted equipment. Vertical (0U) PDUs attach to the side rails of the rack. This maximizes space and provides easy access to outlets.

Connecting Devices to Your Basic PDU

After mounting, connect all lab devices to the PDU outlets. Insert each power cord firmly into its respective receptacle. Verify that all connections are secure. This prevents accidental disconnections and ensures consistent power delivery.

Effective Cable Management Tips

Organized cables improve airflow and simplify maintenance. Use Velcro straps or zip ties to bundle cables neatly. Route power cables away from data cables to minimize interference. Labeling cables helps identify connections quickly during troubleshooting.

Optimizing Basic PDU Usage in Your Home Lab

Load Balancing Across Outlets

Distribute the power load evenly across the PDU’s outlets. This prevents any single circuit from becoming overloaded. To mitigate PDU overloading risks, determine the power requirements of each device. Then, distribute the load evenly across available PDUs. Utilizing real-time power monitoring tools can track energy usage. These tools provide actionable insights for better power management.

Regular Inspections and Maintenance

Periodically inspect the PDU and its connections. Check for loose cables, damaged outlets, or signs of overheating. Ensure the PDU’s circuit breakers are not tripped. Regular checks help identify potential issues before they cause downtime.

Environmental Considerations for PDU Placement

The operating environment impacts PDU performance. For optimal PDU operation, maintain a temperature between 18-27°C. Humidity levels should remain between 40-60%. Proper airflow around the PDU also prevents overheating.

Safety First with Your Basic PDU

Overload Prevention Strategies

Overloading a PDU poses significant risks. These include overheating, breaker trips, and potential damage to critical power supply systems. Overload detection features help identify potential issues before they escalate. This ensures efficient power distribution and reduces downtime risks. Distribute the load evenly across PDUs and regularly assess for imbalances.

Proper Grounding Techniques

Always ensure the PDU and all connected equipment are properly grounded. Grounding protects against electrical surges and reduces the risk of electric shock. Use grounded outlets and power cords.

Avoiding Daisy Chaining Basic PDUs

Never daisy-chain PDUs. Connecting one PDU to another creates several hazards. These include circuit overload, increased resistance, and degraded surge protection performance. Always plug each PDU directly into a dedicated wall outlet or UPS.


This guide explored top budget-friendly Basic PDUs for home labs. We reviewed various models, each offering distinct features. Users should carefully consider their specific needs. These include required outlet count, voltage compatibility, and available space. Choosing the right Basic PDU empowers a home lab. It ensures reliable power distribution and enhances organization. This thoughtful selection optimizes both performance and safety for all connected equipment.

FAQ

What is the difference between a Basic PDU and a surge protector?

A Basic PDU distributes power. It acts like a robust power strip. A surge protector defends equipment from voltage spikes. Some Basic PDUs include surge protection, but not all. Users should check specifications for this feature.

Can a Basic PDU protect my equipment from power outages?

No, a Basic PDU does not protect against power outages. It only distributes power. For outage protection, users need an Uninterruptible Power Supply (UPS). A UPS provides temporary battery backup power.

How do I know what amperage PDU I need?

Users determine the total power draw of all connected devices. The PDU’s amperage rating must exceed this sum. For example, a 15A PDU supports devices drawing less than 15 amps combined. Always leave some headroom.

Is it safe to plug multiple power strips into a PDU?

No, users should avoid “daisy-chaining” power strips into a PDU. This practice creates fire hazards and overloads circuits. Each device should plug directly into the PDU or a single, properly rated power strip.

What does “0U rackmount” mean?

“0U rackmount” refers to a vertical PDU. It mounts along the side of a server rack. This design saves horizontal rack space. It allows users to install more equipment in the rack’s front.

Do Basic PDUs come with power cords?

Most Basic PDUs include an attached power cord. The cord connects the PDU to a wall outlet or UPS. Users should verify the cord length and plug type before purchasing. Some models may require a separate input cable.

Can I use a Basic PDU for non-lab equipment?

Yes, users can employ a Basic PDU for non-lab equipment. It functions as a reliable power distribution unit. However, it lacks advanced features like individual outlet control. Consider specific needs for optimal use.

What is the typical lifespan of a Basic PDU?

A well-maintained Basic PDU can last many years. Its lifespan depends on usage and environmental conditions. High-quality units from reputable brands often offer extended durability. Regular inspections help ensure longevity.


Post time: Nov-17-2025

Build your own PDU